ProfileOptions.Builder

מחלקה סופית סטטית ציבורית ProfileOptions.Builder

 Next ID: 11
 
סוג Protobuf tensorflow.ProfileOptions

שיטות ציבוריות

ProfileOptions.Builder
addRepeatedField (שדה com.google.protobuf.Descriptors.FieldDescriptor, ערך אובייקט)
אפשרויות פרופיל
אפשרויות פרופיל
ProfileOptions.Builder
ProfileOptions.Builder
clearDeviceTracerLevel ()
 Levels of device tracing: (version >= 1)
 - Level 0 is used to disable device traces.
ProfileOptions.Builder
clearDeviceType ()
 Device type to profile/trace: (version >= 1)
 DeviceType::UNSPECIFIED: All registered device profiler will be enabled.
ProfileOptions.Builder
clearDurationMs ()
 The local profiler collects `duration_ms` milliseconds of data.
ProfileOptions.Builder
clearEnableHloProto ()
 Whether serialize hlo_proto when XLA is used.
ProfileOptions.Builder
clearField (שדה com.google.protobuf.Descriptors.FieldDescriptor)
ProfileOptions.Builder
clearHostTracerLevel ()
 Levels of host tracing: (version >= 1)
 - Level 0 is used to disable host traces.
ProfileOptions.Builder
clearIncludeDatasetOps ()
 We don't collect the dataset ops by default for better trace-viewer
 scalability.
ProfileOptions.Builder
clearOneof (com.google.protobuf.Descriptors.OneofDescriptor oneof)
ProfileOptions.Builder
clearPythonTracerLevel ()
 Whether enable python function calls tracing.
ProfileOptions.Builder
clearRepositoryPath ()
 Directory to save profile data to.
ProfileOptions.Builder
clearStartTimestampNs ()
 The local profiler starts profiling at this Unix timestamp in nanoseconds.
ProfileOptions.Builder
clearVersion ()
 Some default value of option are not proto3 default value.
ProfileOptions.Builder
אפשרויות פרופיל
final static com.google.protobuf.Descriptors.Descriptor
com.google.protobuf.Descriptors.Descriptor
int
getDeviceTracerLevel ()
 Levels of device tracing: (version >= 1)
 - Level 0 is used to disable device traces.
ProfileOptions.DeviceType
getDeviceType ()
 Device type to profile/trace: (version >= 1)
 DeviceType::UNSPECIFIED: All registered device profiler will be enabled.
int
getDeviceTypeValue ()
 Device type to profile/trace: (version >= 1)
 DeviceType::UNSPECIFIED: All registered device profiler will be enabled.
ארוך
getDurationMs ()
 The local profiler collects `duration_ms` milliseconds of data.
בוליאני
getEnableHloProto ()
 Whether serialize hlo_proto when XLA is used.
int
getHostTracerLevel ()
 Levels of host tracing: (version >= 1)
 - Level 0 is used to disable host traces.
בוליאני
getIncludeDatasetOps ()
 We don't collect the dataset ops by default for better trace-viewer
 scalability.
int
getPythonTracerLevel ()
 Whether enable python function calls tracing.
חוּט
getRepositoryPath ()
 Directory to save profile data to.
com.google.protobuf.ByteString
getRepositoryPathBytes ()
 Directory to save profile data to.
ארוך
getStartTimestampNs ()
 The local profiler starts profiling at this Unix timestamp in nanoseconds.
int
getVersion ()
 Some default value of option are not proto3 default value.
בוליאנית סופית
ProfileOptions.Builder
mergeFrom (com.google.protobuf.Message אחר)
ProfileOptions.Builder
mergeFrom (קלט com.google.protobuf.CodedInputStream, com.google.protobuf.ExtensionRegistryLite extensionRegistry)
final ProfileOptions.Builder
mergeUnknownFields (com.google.protobuf.UnknownFieldSet unknownFields)
ProfileOptions.Builder
setDeviceTracerLevel (ערך int)
 Levels of device tracing: (version >= 1)
 - Level 0 is used to disable device traces.
ProfileOptions.Builder
setDeviceType (ערך ProfileOptions.DeviceType )
 Device type to profile/trace: (version >= 1)
 DeviceType::UNSPECIFIED: All registered device profiler will be enabled.
ProfileOptions.Builder
setDeviceTypeValue (ערך int)
 Device type to profile/trace: (version >= 1)
 DeviceType::UNSPECIFIED: All registered device profiler will be enabled.
ProfileOptions.Builder
setDurationMs (ערך ארוך)
 The local profiler collects `duration_ms` milliseconds of data.
ProfileOptions.Builder
setEnableHloProto (ערך בוליאני)
 Whether serialize hlo_proto when XLA is used.
ProfileOptions.Builder
setField (שדה com.google.protobuf.Descriptors.FieldDescriptor, ערך אובייקט)
ProfileOptions.Builder
setHostTracerLevel (ערך int)
 Levels of host tracing: (version >= 1)
 - Level 0 is used to disable host traces.
ProfileOptions.Builder
setIncludeDatasetOps (ערך בוליאני)
 We don't collect the dataset ops by default for better trace-viewer
 scalability.
ProfileOptions.Builder
setPythonTracerLevel (ערך int)
 Whether enable python function calls tracing.
ProfileOptions.Builder
setRepeatedField (שדה com.google.protobuf.Descriptors.FieldDescriptor, אינדקס אינט, ערך אובייקט)
ProfileOptions.Builder
setRepositoryPath (ערך מחרוזת)
 Directory to save profile data to.
ProfileOptions.Builder
setRepositoryPathBytes (ערך com.google.protobuf.ByteString)
 Directory to save profile data to.
ProfileOptions.Builder
setStartTimestampNs (ערך ארוך)
 The local profiler starts profiling at this Unix timestamp in nanoseconds.
final ProfileOptions.Builder
setUnknownFields (com.google.protobuf.UnknownFieldSet unknownFields)
ProfileOptions.Builder
setVersion (ערך int)
 Some default value of option are not proto3 default value.

שיטות בירושה

שיטות ציבוריות

public ProfileOptions.Builder addRepeatedField (שדה com.google.protobuf.Descriptors.FieldDescriptor, ערך אובייקט)

בניית אפשרויות פרופיל ציבורי ()

Public ProfileOptions buildPartial ()

public ProfileOptions.Builder clear ()

public ProfileOptions.Builder clearDeviceTracerLevel ()

 Levels of device tracing: (version >= 1)
 - Level 0 is used to disable device traces.
 - Level 1 is used to enable device traces.
 - More levels might be defined for specific device for controlling the
   verbosity of the trace.
 
uint32 device_tracer_level = 3;

public ProfileOptions.Builder clearDeviceType ()

 Device type to profile/trace: (version >= 1)
 DeviceType::UNSPECIFIED: All registered device profiler will be enabled.
 DeviceType::CPU: only CPU will be profiled.
 DeviceType::GPU: only CPU/GPU will be profiled.
 DeviceType::TPU: only CPU/TPU will be profiled.
 
.tensorflow.ProfileOptions.DeviceType device_type = 6;

public ProfileOptions.Builder clearDurationMs ()

 The local profiler collects `duration_ms` milliseconds of data. If the
 value is 0, profiling continues until interrupted.
 
uint64 duration_ms = 9;

public ProfileOptions.Builder clearEnableHloProto ()

 Whether serialize hlo_proto when XLA is used. (version >= 1)
 
bool enable_hlo_proto = 7;

public ProfileOptions.Builder clearField (שדה com.google.protobuf.Descriptors.FieldDescriptor)

public ProfileOptions.Builder clearHostTracerLevel ()

 Levels of host tracing: (version >= 1)
 - Level 0 is used to disable host traces.
 - Level 1 enables tracing of only user instrumented (or default) TraceMe.
 - Level 2 enables tracing of all level 1 TraceMe(s) and instrumented high
           level program execution details (expensive TF ops, XLA ops, etc).
           This is the default.
 - Level 3 enables tracing of all level 2 TraceMe(s) and more verbose
           (low-level) program execution details (cheap TF ops, etc).
 
uint32 host_tracer_level = 2;

public ProfileOptions.Builder clearIncludeDatasetOps ()

 We don't collect the dataset ops by default for better trace-viewer
 scalability. The caller can mannually set this field to include the ops.
 
bool include_dataset_ops = 1;

public ProfileOptions.Builder clearOneof (com.google.protobuf.Descriptors.OneofDescriptor oneof)

public ProfileOptions.Builder clearPythonTracerLevel ()

 Whether enable python function calls tracing. Runtime overhead ensues if
 enabled. Default off. (version >= 1)
 
uint32 python_tracer_level = 4;

public ProfileOptions.Builder clearRepositoryPath ()

 Directory to save profile data to. No-op when empty.
 
string repository_path = 10;

public ProfileOptions.Builder clearStartTimestampNs ()

 The local profiler starts profiling at this Unix timestamp in nanoseconds.
 
uint64 start_timestamp_ns = 8;

public ProfileOptions.Builder clearVersion ()

 Some default value of option are not proto3 default value. Use this version
 to determine if we should use default option value instead of proto3
 default value.
 
uint32 version = 5;

public ProfileOptions.Builder שיבוט ()

public ProfileOptions getDefaultInstanceForType ()

public static final com.google.protobuf.Descriptors.Descriptor getDescriptor ()

public com.google.protobuf.Descriptors.Descriptor getDescriptorForType ()

public int getDeviceTracerLevel ()

 Levels of device tracing: (version >= 1)
 - Level 0 is used to disable device traces.
 - Level 1 is used to enable device traces.
 - More levels might be defined for specific device for controlling the
   verbosity of the trace.
 
uint32 device_tracer_level = 3;

public ProfileOptions.DeviceType getDeviceType ()

 Device type to profile/trace: (version >= 1)
 DeviceType::UNSPECIFIED: All registered device profiler will be enabled.
 DeviceType::CPU: only CPU will be profiled.
 DeviceType::GPU: only CPU/GPU will be profiled.
 DeviceType::TPU: only CPU/TPU will be profiled.
 
.tensorflow.ProfileOptions.DeviceType device_type = 6;

public int getDeviceTypeValue ()

 Device type to profile/trace: (version >= 1)
 DeviceType::UNSPECIFIED: All registered device profiler will be enabled.
 DeviceType::CPU: only CPU will be profiled.
 DeviceType::GPU: only CPU/GPU will be profiled.
 DeviceType::TPU: only CPU/TPU will be profiled.
 
.tensorflow.ProfileOptions.DeviceType device_type = 6;

public long getDurationMs ()

 The local profiler collects `duration_ms` milliseconds of data. If the
 value is 0, profiling continues until interrupted.
 
uint64 duration_ms = 9;

getEnableHloProto ציבורי בוליאני ()

 Whether serialize hlo_proto when XLA is used. (version >= 1)
 
bool enable_hlo_proto = 7;

public int getHostTracerLevel ()

 Levels of host tracing: (version >= 1)
 - Level 0 is used to disable host traces.
 - Level 1 enables tracing of only user instrumented (or default) TraceMe.
 - Level 2 enables tracing of all level 1 TraceMe(s) and instrumented high
           level program execution details (expensive TF ops, XLA ops, etc).
           This is the default.
 - Level 3 enables tracing of all level 2 TraceMe(s) and more verbose
           (low-level) program execution details (cheap TF ops, etc).
 
uint32 host_tracer_level = 2;

getIncludeDatasetOps ציבורי בוליאני ()

 We don't collect the dataset ops by default for better trace-viewer
 scalability. The caller can mannually set this field to include the ops.
 
bool include_dataset_ops = 1;

public int getPythonTracerLevel ()

 Whether enable python function calls tracing. Runtime overhead ensues if
 enabled. Default off. (version >= 1)
 
uint32 python_tracer_level = 4;

מחרוזת ציבורית getRepositoryPath ()

 Directory to save profile data to. No-op when empty.
 
string repository_path = 10;

public com.google.protobuf.ByteString getRepositoryPathBytes ()

 Directory to save profile data to. No-op when empty.
 
string repository_path = 10;

public long getStartTimestampNs ()

 The local profiler starts profiling at this Unix timestamp in nanoseconds.
 
uint64 start_timestamp_ns = 8;

public int getVersion ()

 Some default value of option are not proto3 default value. Use this version
 to determine if we should use default option value instead of proto3
 default value.
 
uint32 version = 5;

בוליאני הסופי הציבורי הוא אתחול ()

public ProfileOptions.Builder mergeFrom (com.google.protobuf.Message אחר)

public ProfileOptions.Builder mergeFrom (com.google.protobuf.CodedInputStream קלט, com.google.protobuf.ExtensionRegistryLite extensionRegistry)

זורק
IOException

public final ProfileOptions.Builder mergeUnknownFields (com.google.protobuf.UnknownFieldSet unknownFields)

public ProfileOptions.Builder setDeviceTracerLevel (ערך int)

 Levels of device tracing: (version >= 1)
 - Level 0 is used to disable device traces.
 - Level 1 is used to enable device traces.
 - More levels might be defined for specific device for controlling the
   verbosity of the trace.
 
uint32 device_tracer_level = 3;

public ProfileOptions.Builder setDeviceType (ערך ProfileOptions.DeviceType )

 Device type to profile/trace: (version >= 1)
 DeviceType::UNSPECIFIED: All registered device profiler will be enabled.
 DeviceType::CPU: only CPU will be profiled.
 DeviceType::GPU: only CPU/GPU will be profiled.
 DeviceType::TPU: only CPU/TPU will be profiled.
 
.tensorflow.ProfileOptions.DeviceType device_type = 6;

public ProfileOptions.Builder setDeviceTypeValue (ערך int)

 Device type to profile/trace: (version >= 1)
 DeviceType::UNSPECIFIED: All registered device profiler will be enabled.
 DeviceType::CPU: only CPU will be profiled.
 DeviceType::GPU: only CPU/GPU will be profiled.
 DeviceType::TPU: only CPU/TPU will be profiled.
 
.tensorflow.ProfileOptions.DeviceType device_type = 6;

public ProfileOptions.Builder setDurationMs (ערך ארוך)

 The local profiler collects `duration_ms` milliseconds of data. If the
 value is 0, profiling continues until interrupted.
 
uint64 duration_ms = 9;

public ProfileOptions.Builder setEnableHloProto (ערך בוליאני)

 Whether serialize hlo_proto when XLA is used. (version >= 1)
 
bool enable_hlo_proto = 7;

public ProfileOptions.Builder setField (שדה com.google.protobuf.Descriptors.FieldDescriptor, ערך אובייקט)

public ProfileOptions.Builder setHostTracerLevel (ערך int)

 Levels of host tracing: (version >= 1)
 - Level 0 is used to disable host traces.
 - Level 1 enables tracing of only user instrumented (or default) TraceMe.
 - Level 2 enables tracing of all level 1 TraceMe(s) and instrumented high
           level program execution details (expensive TF ops, XLA ops, etc).
           This is the default.
 - Level 3 enables tracing of all level 2 TraceMe(s) and more verbose
           (low-level) program execution details (cheap TF ops, etc).
 
uint32 host_tracer_level = 2;

public ProfileOptions.Builder setIncludeDatasetOps (ערך בוליאני)

 We don't collect the dataset ops by default for better trace-viewer
 scalability. The caller can mannually set this field to include the ops.
 
bool include_dataset_ops = 1;

public ProfileOptions.Builder setPythonTracerLevel (ערך int)

 Whether enable python function calls tracing. Runtime overhead ensues if
 enabled. Default off. (version >= 1)
 
uint32 python_tracer_level = 4;

public ProfileOptions.Builder setRepeatedField (שדה com.google.protobuf.Descriptors.FieldDescriptor, אינדקס אינט, ערך אובייקט)

public ProfileOptions.Builder setRepositoryPath (ערך מחרוזת)

 Directory to save profile data to. No-op when empty.
 
string repository_path = 10;

public ProfileOptions.Builder setRepositoryPathBytes (ערך com.google.protobuf.ByteString)

 Directory to save profile data to. No-op when empty.
 
string repository_path = 10;

public ProfileOptions.Builder setStartTimestampNs (ערך ארוך)

 The local profiler starts profiling at this Unix timestamp in nanoseconds.
 
uint64 start_timestamp_ns = 8;

public final ProfileOptions.Builder setUnknownFields (com.google.protobuf.UnknownFieldSet unknownFields)

public ProfileOptions.Builder setVersion (ערך int)

 Some default value of option are not proto3 default value. Use this version
 to determine if we should use default option value instead of proto3
 default value.
 
uint32 version = 5;